FT-Cホルダー
サニタリーブレード付きプリアッセンブリー型ホルダー
性能
- セーフティヘッドの側面に刻印されているフロー矢印は、正しいフロー方向を示します
- サニタリートライクランプ配管接続に使用
- 表面仕上げは規格に応じて指定可
- 生成物の蓄積を最小限に抑えデッドレッグを軽減します
お問い合わせはこちらから
Sizes & Pressures
FT-C™ Disk Specifications Minimum/Maximum Pressure with Rating at 72° (22°C)
Sanitary Fitting | Burst Pressure | Overall Height | OD | ||||||
Disk Size | min | max | |||||||
in | mm | psi | bar | psi | bar | in | mm | in | mm |
---|---|---|---|---|---|---|---|---|---|
1.5 | 40 | 10 | 0.69 | 300 | 20.7 | 1.62 | 41 | 1.98 | 50.3 |
2 | 50 | 10 | 0.69 | 300 | 20.7 | 1.62 | 41 | 5.52 | 64 |
3 | 80 | 10 | 0.69 | 175 | 12.1 | 1.81 | 46 | 3.58 | 90.9 |
4 | 100 | 10 | 0.69 | 75 | 5.2 | 1.81 | 46 | 4.68 | 118.9 |
Rupture Disks
Standard Materials
316 stainless steel and carbon steel.
Also available Monel® alloy 400, Inconel® alloy 600, Hastelloy® alloy C and C-276, aluminum, and titanium.
Torque Resistant Safety Head Option
The Type TR™ Series torque resistant safety head option offers the identical performance and flow characteristics valued from standard BS&B safety heads. The only difference – the TR Series Safety Heads are designed with a wider seating surface to be used with metal spiral wound gaskets at the flange. This distinct safety feature protects rupture disks from situations where plant personnel may overtorque rupture disks within piping systems.
Because of the wider seating surface of the TR Series Safety Head, the load is distributed over a much broader area reducing the influence of excessive torque transmitted to the disk.
Accessories
BS&B supplies many of the accessories required to safely and conveniently install our overpressure relief devices and complementary products. Through our professional team and global network of sales engineers and procurement personnel, we are able to provide the highest quality accessory products to meet your installation requirements.
Saf-T-Change Quick Disk Replacement (QDR)
After activation, the replacement disk is quickly slid into place. Saving hours of lost production due to blown rupture disks.
Tell-Tale Assemblies & Excess Flow Valves/Gauges
A gauge tap in the outlet flange of the safety head may be considered when the safety head is installed in a vertical position.
Spare Safety Heads & Cap Screws
Jackscrews
When activated, the jackscrews effectively separate the flanges, providing adequate clearance to remove or insert a safety head and external gaskets.
Lifting Lug Eye Bolts
Eye bolts are recommended when weight and/or accessibility is a factor in lifting safety heads.
Baffle Plate
When a safety head is free-vented to atmosphere, a baffle plate may be considered to disperse overpressure and absorb recoil.
Sizes & Pressures
FT-C™ Disk Specifications Minimum/Maximum Pressure with Rating at 72° (22°C)
Sanitary Fitting | Burst Pressure | Overall Height | OD | ||||||
Disk Size | min | max | |||||||
in | mm | psi | bar | psi | bar | in | mm | in | mm |
---|---|---|---|---|---|---|---|---|---|
1.5 | 40 | 10 | 0.69 | 300 | 20.7 | 1.62 | 41 | 1.98 | 50.3 |
2 | 50 | 10 | 0.69 | 300 | 20.7 | 1.62 | 41 | 5.52 | 64 |
3 | 80 | 10 | 0.69 | 175 | 12.1 | 1.81 | 46 | 3.58 | 90.9 |
4 | 100 | 10 | 0.69 | 75 | 5.2 | 1.81 | 46 | 4.68 | 118.9 |
Rupture Disks
Standard Materials
316 stainless steel and carbon steel.
Also available Monel® alloy 400, Inconel® alloy 600, Hastelloy® alloy C and C-276, aluminum, and titanium.
Torque Resistant Safety Head Option
The Type TR™ Series torque resistant safety head option offers the identical performance and flow characteristics valued from standard BS&B safety heads. The only difference – the TR Series Safety Heads are designed with a wider seating surface to be used with metal spiral wound gaskets at the flange. This distinct safety feature protects rupture disks from situations where plant personnel may overtorque rupture disks within piping systems.
Because of the wider seating surface of the TR Series Safety Head, the load is distributed over a much broader area reducing the influence of excessive torque transmitted to the disk.
Accessories
BS&B supplies many of the accessories required to safely and conveniently install our overpressure relief devices and complementary products. Through our professional team and global network of sales engineers and procurement personnel, we are able to provide the highest quality accessory products to meet your installation requirements.
Saf-T-Change Quick Disk Replacement (QDR)
After activation, the replacement disk is quickly slid into place. Saving hours of lost production due to blown rupture disks.
Tell-Tale Assemblies & Excess Flow Valves/Gauges
A gauge tap in the outlet flange of the safety head may be considered when the safety head is installed in a vertical position.
Spare Safety Heads & Cap Screws
Jackscrews
When activated, the jackscrews effectively separate the flanges, providing adequate clearance to remove or insert a safety head and external gaskets.
Lifting Lug Eye Bolts
Eye bolts are recommended when weight and/or accessibility is a factor in lifting safety heads.
Baffle Plate
When a safety head is free-vented to atmosphere, a baffle plate may be considered to disperse overpressure and absorb recoil.